← Back to search

HAWAII ENERGY SYSTEMS LLC

AIEA, HI, 96701

Prime contracting experience

1 record from government sources. Past participation is not evidence of current teaming interest.

RoleAgencyDescriptionVehicleObligatedAction datePeriod
Prime
Department of Defense
Department of the Air Force
HVAC DIRECT DIGITAL CONTROLS (DDC) SYSTEMS UPGRADE AT VARIOUS BLDGS ON ANDERSON AFB, GUAM—$480,460Sep 11, 2023Sep 15, 2023 – Sep 14, 2024

Contract vehicles are shown only when present in the source record. Linked award numbers and vehicles open the authoritative record on USAspending.gov.

Subcontracting experience

7 records from government sources. Past participation is not evidence of current teaming interest.

RoleAgencyDescriptionVehicleObligatedAction datePeriod
Subcontractor
Department of Defense
SEE REMARKS
1000090332
Parent award context
Parent award agency: Department of Defense · Department of the Navy
Parent award NAICS: 336611
Parent award performance state: CT
Parent award description: SUBMARINE PLANNING YARD
View parent award on USAspending
—$12,000Oct 7, 2024— – —
Subcontractor
Department of Defense
SEE REMARKS
1000090332
Parent award context
Parent award agency: Department of Defense · Department of the Navy
Parent award NAICS: 336611
Parent award performance state: CT
Parent award description: SUBMARINE PLANNING YARD
View parent award on USAspending
—$12,000Oct 7, 2024— – —
Subcontractor
Department of Defense
CLIN 0001 REPLACE AIR COOLED CHILLER 1&2: SUPPLY AND CONTROL FOR THE FOLLOWING EQUIPMENT: TO INCLUDE: ▪ CONNECT 2 (TWO) NEW CHILLERS TO EXISTING ALERTON CONTROL SYSTEM VIA BACNET INTERFACE ▪ CHILLER DDC NEMA RATED CONTROL PANEL COMPLETE WITH ACCESSORIES AND DEVICES ▪ INTERFACE TO THE FACTORY SUPPLIED BACNET CAPABLE CHILLER UNIT CONTROLLER PER SPECIFICATIONS. ▪ INTEGRATION/CONFIGURATION TO THE DDC SYSTEM SHALL BE PROVIDED BY EQUIPMENT MANUFACTURER. ▪ DDC BACNET CAPABLE CONTROLLER TO CONTROL; ▪ CHILLED WATER PUMPS WITH VFD (BY OTHERS) FOR 3 REPLACEMENT PUMPS ▪ CHILLED WATER VALVES, INSTALLED BY MECH CONTRACTOR: 4 EACH ISOLATION VALVES ▪ DIFFERENTIAL PRESSURE TRANSMITTERS (WET), INSTALLED BY MECH CONTRACTOR ▪ TEMPERATURE SENSORS(4 EA.) WITH IMMERSION WELL, INSTALLED BY MECH CONTRACTOR ▪ FLOW METER (1 EA.), INSTALLED BY MECH. CONTRACTOR   CLIN 0002 SECONDARY CHILLED WATER SYSTEM PUMP VFDS: SUPPLY AND CONTROL FOR THE FOLLOWING EQUIPMENT: TO INCLUDE: ▪ CONNECT THE NEW VFDS TO THE EXISTING ALERTON BUILDING AUTOMATION SYSTEM VIA BACNET INTERFACE CARD PROVIDED BY VFD MANUFACTURER. ▪ UPDATE THE EXISTING BUILDING AUTOMATION GRAPHICS TO THE NEW VFDS (VFDS SUPPLIED BY OTHERS). CLIN 0003 REPLACE SECONDARY CHILLED WATER SYSTEM TEMPERATURE SENSORS: SUPPLY AND CONTROL FOR THE FOLLOWING EQUIPMENT: TO INCLUDE: ▪ SUPPLY TEMPERATURE SENSORS(4 EA.) WITH IMMERSION WELL, INSTALLED BY MECH CONTRACTOR ▪ UPDATE THE EXISTING BUILDING AUTOMATION GRAPHICS TO CORRECTLY CALCULATE THE SECONDARY CHILLED WATER SYSTEM TONNAGE. CLIN 0004 REPLACE AIR COOLED CHILLER 3: SUPPLY AND CONTROL FOR THE FOLLOWING EQUIPMENT: TO INCLUDE: ▪ CONNECT THE NEW CHILLER UNIT TO EXISTING ALERTON CONTROL SYSTEM VIA BACNET INTERFACE ▪ CHILLER DDC NEMA RATED CONTROL PANEL COMPLETE WITH ACCESSORIES AND DEVICES ▪ INTERFACE TO THE FACTORY SUPPLIED BACNET CAPABLE CHILLER UNIT CONTROLLER PER SPECIFICATIONS. ▪ INTEGRATION/CONFIGURATION TO THE DDC SYSTEM SHALL BE PROVIDED BY EQUIPMENT MANUFACTURER. ▪ DDC BACNET CAPABLE CONTROLLER TO CONTROL; ▪ CHILLED WATER PUMPS WITH VFD (BY OTHERS) FOR 1 REPLACEMENT PUMPS ▪ CHILLED WATER VALVES, INSTALLED BY MECH CONTRACTOR: 2 EACH ISOLATION VALVES ▪ DIFFERENTIAL PRESSURE TRANSMITTERS (WET), INSTALLED BY MECH CONTRACTOR ▪ TEMPERATURE SENSORS(2 EA.) WITH IMMERSION WELL, INSTALLED BY MECH CONTRACTOR CLIN 0006 REPLACE FAILED BUILDING AUTOMATION EQUIPMENT: SUPPLY AND CONTROL FOR THE FOLLOWING EQUIPMENT: TO INCLUDE: ▪ FURNISH FAILED SENSORS AND DEVICES FOR RESPECTIVE EQUIPMENT AND QUANTITY LIMITED TO THE ITEMS LISTED IN THE TABLE BELOW ▪ RESTORE THE FAILED SENSORS AND DEVICES TO ALERTON BUILDING AUTOMATION SYSTEM INITIAL DESIGN CONDITIONS
SVI-2319067-APE
Parent award context
Parent award agency: Department of Defense · Department of the Army
Parent award NAICS: 236220
Parent award performance state: GU
Parent award description: BASE REPLACE CHILLERS 1 AND 2
View parent award on USAspending
—$184,494Oct 17, 2023— – —
Subcontractor
Department of Defense
CLIN 0001 REPLACE AIR COOLED CHILLER 1&2: SUPPLY AND CONTROL FOR THE FOLLOWING EQUIPMENT: TO INCLUDE: ▪ CONNECT 2 (TWO) NEW CHILLERS TO EXISTING ALERTON CONTROL SYSTEM VIA BACNET INTERFACE ▪ CHILLER DDC NEMA RATED CONTROL PANEL COMPLETE WITH ACCESSORIES AND DEVICES ▪ INTERFACE TO THE FACTORY SUPPLIED BACNET CAPABLE CHILLER UNIT CONTROLLER PER SPECIFICATIONS. ▪ INTEGRATION/CONFIGURATION TO THE DDC SYSTEM SHALL BE PROVIDED BY EQUIPMENT MANUFACTURER. ▪ DDC BACNET CAPABLE CONTROLLER TO CONTROL; ▪ CHILLED WATER PUMPS WITH VFD (BY OTHERS) FOR 3 REPLACEMENT PUMPS ▪ CHILLED WATER VALVES, INSTALLED BY MECH CONTRACTOR: 4 EACH ISOLATION VALVES ▪ DIFFERENTIAL PRESSURE TRANSMITTERS (WET), INSTALLED BY MECH CONTRACTOR ▪ TEMPERATURE SENSORS(4 EA.) WITH IMMERSION WELL, INSTALLED BY MECH CONTRACTOR ▪ FLOW METER (1 EA.), INSTALLED BY MECH. CONTRACTOR   CLIN 0002 SECONDARY CHILLED WATER SYSTEM PUMP VFDS: SUPPLY AND CONTROL FOR THE FOLLOWING EQUIPMENT: TO INCLUDE: ▪ CONNECT THE NEW VFDS TO THE EXISTING ALERTON BUILDING AUTOMATION SYSTEM VIA BACNET INTERFACE CARD PROVIDED BY VFD MANUFACTURER. ▪ UPDATE THE EXISTING BUILDING AUTOMATION GRAPHICS TO THE NEW VFDS (VFDS SUPPLIED BY OTHERS). CLIN 0003 REPLACE SECONDARY CHILLED WATER SYSTEM TEMPERATURE SENSORS: SUPPLY AND CONTROL FOR THE FOLLOWING EQUIPMENT: TO INCLUDE: ▪ SUPPLY TEMPERATURE SENSORS(4 EA.) WITH IMMERSION WELL, INSTALLED BY MECH CONTRACTOR ▪ UPDATE THE EXISTING BUILDING AUTOMATION GRAPHICS TO CORRECTLY CALCULATE THE SECONDARY CHILLED WATER SYSTEM TONNAGE. CLIN 0004 REPLACE AIR COOLED CHILLER 3: SUPPLY AND CONTROL FOR THE FOLLOWING EQUIPMENT: TO INCLUDE: ▪ CONNECT THE NEW CHILLER UNIT TO EXISTING ALERTON CONTROL SYSTEM VIA BACNET INTERFACE ▪ CHILLER DDC NEMA RATED CONTROL PANEL COMPLETE WITH ACCESSORIES AND DEVICES ▪ INTERFACE TO THE FACTORY SUPPLIED BACNET CAPABLE CHILLER UNIT CONTROLLER PER SPECIFICATIONS. ▪ INTEGRATION/CONFIGURATION TO THE DDC SYSTEM SHALL BE PROVIDED BY EQUIPMENT MANUFACTURER. ▪ DDC BACNET CAPABLE CONTROLLER TO CONTROL; ▪ CHILLED WATER PUMPS WITH VFD (BY OTHERS) FOR 1 REPLACEMENT PUMPS ▪ CHILLED WATER VALVES, INSTALLED BY MECH CONTRACTOR: 2 EACH ISOLATION VALVES ▪ DIFFERENTIAL PRESSURE TRANSMITTERS (WET), INSTALLED BY MECH CONTRACTOR ▪ TEMPERATURE SENSORS(2 EA.) WITH IMMERSION WELL, INSTALLED BY MECH CONTRACTOR CLIN 0006 REPLACE FAILED BUILDING AUTOMATION EQUIPMENT: SUPPLY AND CONTROL FOR THE FOLLOWING EQUIPMENT: TO INCLUDE: ▪ FURNISH FAILED SENSORS AND DEVICES FOR RESPECTIVE EQUIPMENT AND QUANTITY LIMITED TO THE ITEMS LISTED IN THE TABLE BELOW ▪ RESTORE THE FAILED SENSORS AND DEVICES TO ALERTON BUILDING AUTOMATION SYSTEM INITIAL DESIGN CONDITIONS
SVI-2319067-APE
Parent award context
Parent award agency: Department of Defense · Department of the Army
Parent award NAICS: 236220
Parent award performance state: GU
Parent award description: BASE REPLACE CHILLERS 1 AND 2
View parent award on USAspending
—$184,494Oct 17, 2023— – —
Subcontractor
Department of Defense
PREVENTATIVE MAINTENANCE
0002995
Parent award context
Parent award agency: Department of Defense · Department of the Navy
Parent award NAICS: 238220
Parent award performance state: HI
Parent award description: BASE PERIOD FUNDING TASK ORDER (10/5/22 - 10/4/23)
View parent award on USAspending
N6247822D2402USAspending$1,979,082Dec 2, 2022— – —
Subcontractor
Department of Defense
SEE BELOW
1000030889
Parent award context
Parent award agency: Department of Defense · Department of the Navy
Parent award NAICS: 336611
Parent award performance state: CT
Parent award description: SUBMARINE PLANNING YARD
View parent award on USAspending
—$59,347May 10, 2022— – —
Subcontractor
Department of Defense
HVAC SERVICESN6247817D2464USAspending$302,547Oct 20, 2021— – —

Contract vehicles are shown only when present in the source record. Linked award numbers and vehicles open the authoritative record on USAspending.gov.

Agencies supported

  • Department of DefenseGov-sourced

Government-sourced data comes from SAM.gov, SBA and USAspending.gov and is attributed to its source. Items marked company-reported were provided by the company and are verified by FedSub only where labeled. FedSub is a private company and is not affiliated with SBA, GSA/SAM.gov, or any government agency.