← Back to search

UKRSPETSSERVIS TOV

CHERNIGIV

Subcontracting experience

3 records from government sources. Past participation is not evidence of current teaming interest.

RoleAgencyDescriptionVehicleObligatedAction datePeriod
Subcontractor
Agency for International Development
PROCUREMENT AND DELIVERY OF MOBILE BOILER HOUSES TO SPECIFICIED LOCATIONS THROUGHOUT UKRAINE
154-UCEM-1810-1202201
Parent award context
Parent award agency: Agency for International Development · Agency for International Development
Parent award NAICS: 541990
Parent award description: OVERSEAS CONTRACT
View parent award on USAspending
—$3,564,000Sep 25, 2023— – —
Subcontractor
Agency for International Development
DISTRIBUTION OF BOILER HOUSES BY REGIONS AND CAPACITIES IS SHOWN THE TABLE BELOW: CHERNIHIV & REGION, SUMY & REGION, VINNYTSIA, KRAMATORSK, KROPYVNYT-SKYI, AND ODESA. 1. GENERAL REQUIREMENTS: EXECUTION: CONTAINER MODULAR TRANSPORTABLE THE PURPOSE OF THE BH: HEATING (WITHOUT DHW) TYPE OF FUEL: FIREWOOD, PEAT, WOOD BRIQUETTES, COAL FUEL SUPPLY: MANUAL EFFICIENCY: NOT LESS THAN 85% TEMPERATURE GRAPH: 95° C / 70° C (MAX); 80° C / 60° C (ACCEPTABLE) OPERATING PRESSURE OF COOLANT, MPA: 6.0 CONNECTION SCHEME: DEPENDED SUPPLY VOLTAGE OF ELECTRICAL EQUIPMENT, V: ~380/~220 TECHNOLOGICAL PROTECTION: REQUIRED EMERGENCY PROTECTION: REQUIRED ACTUATION TIME OF PROTECTIVE DEVICES, NO MORE, S: 60 SIGNALING: AUTOMATICALLY FLUE GAS CLEANING: NOT REQUIRED METERS: THERMAL ENERGY, WATER, MAKE-UP WATER, ELECTRICITY GROUNDING: INTERNAL GROUND LOOP THE DESIGN OF THE CONTAINER: NO SPECIAL REQUIREMENTS HEIGHT OF CONTAINER ON THE TRAWL: NO MORE, THAN 3.95 M WIDTH OF THE CONTAINER OR ITS SEPARABLE PARTS: NO MORE, THAN 2.6 M CONTAINER INSULATION: REQUIRED AVERAGE SERVICE LIFE, NOT LESS THAN, YEARS: 15 CONNECT MBH€„¢S PROTECTION AND SAFETY SYSTEMS TO AN UNINTERRUPTED POWER SUPPLY SOURCE. MOBILE BOILER HOUSES WILL BE CONNECTED TO HEAT SUPPLY NETWORKS (STATIC PRESSURE €€Œ UP TO 25 METERS OF WATER COLUMN) AND WATER SUPPLY (PRESSURE €€Œ FROM 0.5 ATM TO 3.0 ATM) USING FLEXIBLE HOSES OF THE APPROPRIATE PARAMETERS ( FLEXIBLE HOSES 10 METERS LONG EACH AND VALVES ARE INCLUDED IN THE DELIVERY). THE MODULE MUST CONTAIN A PROPRIETARY PLATE MARKING PASSPORT DATA AFFIXED IN A PERCUSSION OR OTHER EQUIVALENT WAY, ENSURING THE CLARITY AND DURABILITY OF THE IMAGE, WHICH CONTAINS THE FOLLOWING INFORMATION: A) NAME, TRADEMARK OF THE MANUFACTURER; B) DESIGNATION OF THE MODULE; C) NUMBER ACCORDING TO THE NUMBERING SYSTEM OF THE MANUFACTURER; D) YEAR OF MANUFACTURE; E) INSTALLED CAPACITY, MW; F) WORKING PRESSURE, MPA; G) NOMINAL TEMPERATURE, ºÃ?¡; J) DESIGNATION OF TECHNICAL CONDITIONS; K) CLIMATIC PERFORMANCE. THE BODY SHOULD BE MARKED WITH A SLINGING SCHEME, CENTER OF GRAVITY AND MASS. ALL EQUIPMENT, THAT IS PART OF THE MBH MUST ALSO HAVE NAMEPLATES, WHICH SHOULD CONTAIN THE NAME OF THE MANUFACTURER, SERIAL NUMBER, MAIN TECHNICAL CHARACTERISTICS, YEAR OF MANUFACTURE, ETC. 2. THE COMPOSITION OF THE MOBILE BOILER HOUSES INCLUDES: - SOLID FUEL WATER HEATING BOILER - THRUST REGULATOR THERMOMECHANICAL - BOILER SAFETY GROUP - BOILER RECIRCULATION PUMP, OR A SOLUTION, THAT REPLACES IT - MAIN PUMPS WITH A FREQUENCY CONVERTER - FEED PUMPS - SEDIMENT FILTER - MEMBRANE EXPANSION TANK, UN - PURIFIED WATER SUPPLY TANK WITH FLOAT VALVE, SET - INSTALLATION OF WATER SOFTENING, SET - COLD WATER METER, SET - HEAT METER, SET - BOILER HOUSE CONTROL CABINET, SET - INPUT ELECTRICAL CABINET, SET - THE POWER SUPPLY SYSTEM OF THE BOILER HOUSE, SET - EXTERNAL AND INTERNAL LIGHTING SYSTEM, SET - SUPPLY AND EXHAUST VENTILATION SYSTEM, SET - PIPELINES AND FITTINGS OF THE INTERNAL THERMAL CIRCUIT, SET - PIPELINES AND FITTINGS OF INTERNAL WATER SUPPLY, SET - DRAINAGE PIPELINES, SET - GAS DUCTS WITHIN AND OUTSIDE (MIN) THE BOILER HOUSE, SET - CONTROL AND MEASURING EQUIPMENT AND AUTOMATION, SET - ELECTRIC CONVECTOR, UN - DIESEL-ELECTRIC GENERATOR FOR OWN NEEDS, SET - FIRE CABINET AND POWDER FIRE EXTINGUISHER OP-9 - 2 ELECTRICAL INPUTS (ONE - FROM THE ELECTRICAL NETWORK, THE SECOND (BACKUP) FROM THE DIESEL GENERATOR). 3 TECHNICAL DOCUMENTS TO BE PROVIDED WITH MBH: - PASPORT MBH; - OPERATING INSTRUCTION; - FACTORY TEST REPORTS; - PASSPORTS AND OPERATING INSTRUCTIONS FOR EQUIPMENT INCLUDED IN THE MBH; - WARRANTY CARDS FOR EQUIPMENT€„¢S; - DRAWING: DIAGRAMS, SPECIFICATIONS, PLANS, SECTIONS ALL EQUIPMENT SHALL BE OF INDUSTRIAL GRADE AND OF STANDARD CONSTRUCTION, STURDY DESIGN AND MANUFACTURED NO EARLIER THAN 2022. WARRANTY €€Œ AT LEAST 2 YEARS. THE PRESENCE OF SERVICE CENTERS IN UKRAINE, INCLUDING FOR MAIN
154-UCEM-1810-1201641
Parent award context
Parent award agency: Agency for International Development · Agency for International Development
Parent award NAICS: 541990
Parent award description: OVERSEAS CONTRACT
View parent award on USAspending
—$3,329,103Sep 5, 2023— – —
Subcontractor
Agency for International Development
BOILERHOUSES FOR ESP BENEFICIARIES
154-UCEM-1810-1194905
Parent award context
Parent award agency: Agency for International Development · Agency for International Development
Parent award NAICS: 541990
Parent award description: OVERSEAS CONTRACT
View parent award on USAspending
—$1,963,092Dec 20, 2022— – —

Contract vehicles are shown only when present in the source record. Linked award numbers and vehicles open the authoritative record on USAspending.gov.

Government-sourced data comes from SAM.gov, SBA and USAspending.gov and is attributed to its source. Items marked company-reported were provided by the company and are verified by FedSub only where labeled. FedSub is a private company and is not affiliated with SBA, GSA/SAM.gov, or any government agency.

UKRSPETSSERVIS TOV – Chernigiv | UEI S7JMV77AFY92 | FedSub