Create a free account to keep browsing
It takes 30 seconds. You can open three notice pages a day without an account; a free account opens every notice, and lists the ones in your NAICS codes.
Graphite Furnace Atomic Absorption Spectrometer
National Institute of Standards and Technology · DEPT OF COMMERCE NIST
Respond by: Nov 28, 2026, 2:00 PM UTC−529 days left
From SAM.gov's public data file generated Oct 29, 2026, 3:30 AM UTC; newest notice posted Oct 29, 2026; loaded into FedSub Oct 29, 2026, 5:46 AM UTC
Notice facts
Source: SAM.gov Contract Opportunities public data file
- Solicitation number
- NIST-MML-FY27-SS01
- Notice type
- Sources sought
- Posted
- Oct 28, 2026
- Response date
- Respond by Nov 28, 2026, 2:00 PM UTC−5
- Set-aside
- None stated
- NAICS code
- 334516 Analytical Laboratory Instrument Manufacturing
- Product or service code
- 6640
- Place of performance
- Gaithersburg, MD
- Contracting office
- DEPT OF COMMERCE NIST (1333ND)GAITHERSBURG, MD 20899
- Agency
- Department of Commerce · National Institute of Standards and Technology
Past prime awardees
Source: Award history, not a list of bidders on this notice
Past prime awardees · award history, not a list of bidders on this notice
103 companies held prime contracts from this office under NAICS 334516.
- FEI COMPANY · No first-tier subawards reported in FedSub's data
24 more past prime awardees on Professional
Description
Source: SAM.gov Contract Opportunities public data file
Sources Sought Notice for Graphite Furnace Atomic Absorption Spectrometer Notice ID: NIST-MML-FY27-SS01 Response Date: 11/28/2026 Product Service Code (PSC): 6640 NAICS Code: 334516 Background The Inorganic Chemical Metrology Group (ICMG) uses at least two measurement methods, each based on orthogonal physical principles, to certify the trace elements in candidate standard reference materials (SRM). These SRMs are intended for method validation and quality assurance in trace-element measurements to assess the nutritional value and contaminant status of agricultural products. A sensitive trace-element detector, a graphite furnace atomic absorption spectrometer (GFAAS) is sought to complement the group's inductively coupled plasma mass spectrometric (ICP-MS) measurement capability and fulfill the two independent method requirements for SRM development. Consideration will be given to GFAAS capable of direct solid-sample analysis to maximize its orthogonality relative to the liquid-sampling-based ICP-MS technique. Minimum Capabilities that NIST Requires and for Which Information is Being Requested The National Institute for Standards and Technology (NIST) located in Gaithersburg, MD is seeking information on vendors that are capable of providing a graphite furnace atomic absorption spectrometer (1) capable of measuring liquid test samples with an instrument detection limit (DL) for Cu at 0.02 µg/L or better (324.8 nm line, 50 µL sample volume, DL=3 x standard deviation of 10 replications) and (2) designed for direct introduction of solid state test samples into the graphite furnace for analyte quantification without a need of sample digestion Instructions for Responding to This Notice Parties that respond to this Notice are requested to submit the requested information via email in Microsoft Word, Adobe PDF, and/or Microsoft Excel format to the designated point(s) of contact whose name and email address appears at the bottom of this notice. Please provide only the…
Versions on SAM.gov
Source: SAM.gov Contract Opportunities public data file
Posted Oct 28, 2026Sources soughtCurrent version
Respond by Nov 28, 2026, 2:00 PM UTC−5
This version on SAM.gov (opens SAM.gov in a new tab)