P7777 ACC SARP Replacement NAS Jacksonville, Florida - Accurate Lock & Hardware
Department of the Navy · NAVFACSYSCOM SOUTHEAST
Respond by: Oct 30, 2026, 3:00 PM UTC−4Less than a day left
From SAM.gov's public data file generated Oct 29, 2026, 3:30 AM UTC; newest notice posted Oct 29, 2026; loaded into FedSub Oct 29, 2026, 5:46 AM UTC
Notice facts
Source: SAM.gov Contract Opportunities public data file
- Solicitation number
- N6945027SP7777-Accurate
- Notice type
- Sources sought
- Posted
- Oct 16, 2026 · Amended Oct 27, 2026
- Response date
- Respond by Oct 30, 2026, 3:00 PM UTC−4
- Set-aside
- None stated
- NAICS code
- None stated
- Place of performance
- Jacksonville, FL
- Contracting office
- NAVFACSYSCOM SOUTHEAST (N69450)NAS JACKSONVILLE, FL 32212
- Agency
- Department of Defense · Department of the Navy
Past prime awardees
Source: Award history, not a list of bidders on this notice
Past prime awardees · award history, not a list of bidders on this notice
This notice lists no NAICS code, so FedSub can't match past awardees.
Description
Source: SAM.gov Contract Opportunities public data file
Notice of intent to use a brand name product. The Naval Facilities Engineering Systems Command, Southeast (NAVFAC SE) is performing a market survey to determine if other potential sources of supply can provide a ligature-resistant sliding door system that has equal performance to the LR-SDS / SL-LR-SDS, manufactured by Accurate Lock & Hardware, 1 Annie Place, Stamford, CT 06902. Fiscal Year 2027 PROJECT P7777 ACC SARP Replacement NAS Jacksonville, Florida, requires the following characteristics. Provide ligature-resistant sliding door system with the following capabilities: Ligature-Resistant Design – A sliding door system specifically designed for behavioral health environments that eliminates ligature opportunities associated with conventional swinging doors, including the top edge of the door and side latch locations. The system shall utilize a concealed overhead track, concealed locking hardware, ligature-resistant operating trim, and concealed vertical rod locking or latching mechanisms with no exposed anchor points or accessible cavities. Threshold and Floor Guide – An anti-barricade floor guide that allows sliding operation without creating additional ligature points. Optional threshold/transom assemblies shall be available to reduce the bottom door gap while allowing emergency access and maintaining safe operation. Safety and Security Features – The system shall reduce opportunities for patient barricading, prevent the door from being used as a swinging weapon, and provide staff override capability for all interior locking functions. Locking functions shall include behavioral health applications such as classroom, storeroom, and self-latching patient room configurations. Performance Requirements – The system shall: Meet or exceed a 150 ft-lb impact test in accordance with ANSI A250.13-2014, Section 6.1.1.2. Continue to function following impact testing. Utilize dual ball-bearing carrier assemblies rated at 1,240 lbs dynamic load capacity each. Where…
Versions on SAM.gov
Source: SAM.gov Contract Opportunities public data file
Posted Oct 27, 2026Sources soughtCurrent version
Respond by Oct 30, 2026, 3:00 PM UTC−4
Changed from the version before: Description
This version on SAM.gov (opens SAM.gov in a new tab)Posted Oct 21, 2026Sources sought
Respond by Oct 30, 2026, 3:00 PM UTC−4
Changed from the version before: Description
This version on SAM.gov (opens SAM.gov in a new tab)Posted Oct 16, 2026Sources sought
Respond by Oct 30, 2026, 3:00 PM UTC−4
This version on SAM.gov (opens SAM.gov in a new tab)