Create a free account to keep browsing
It takes 30 seconds. You can open three notice pages a day without an account; a free account opens every notice, and lists the ones in your NAICS codes.
Repair Naval Reserve Training Facility B3370
Department of the Air Force · FA4418 628 CONS PK
Respond by: Apr 1, 2029, 12:00 PM UTC−4884 days left
From SAM.gov's public data file generated Oct 29, 2026, 3:30 AM UTC; newest notice posted Oct 29, 2026; loaded into FedSub Oct 29, 2026, 5:46 AM UTC
Notice facts
Source: SAM.gov Contract Opportunities public data file
- Solicitation number
- DKGV-1137999
- Notice type
- Sources sought
- Posted
- Mar 17, 2026 · Amended Mar 18, 2026
- Response date
- Respond by Apr 1, 2029, 12:00 PM UTC−4
- Set-aside
- Small Business Set Aside - Total
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Product or service code
- Z2AA
- Place of performance
- Charleston AFB, SC 29404
- Contracting office
- FA4418 628 CONS PKJB LINDSEY GRAHAM, SC 29404
- Agency
- Department of Defense · Department of the Air Force
Past prime awardees
Source: Award history, not a list of bidders on this notice
Past prime awardees · award history, not a list of bidders on this notice
16 companies held prime contracts from this office under NAICS 236220.
- DEFENDER CONTRACTING & CONSTRUCTION LLC · No first-tier subawards reported in FedSub's data
15 more past prime awardees on Professional
Description
Source: SAM.gov Contract Opportunities public data file
The 628th Contracting Squadron at Joint Base Charleston (JBC), SC is seeking capabilities packages from potential sources for planning purposes for the Repair Naval Reserve Training Facility B3370 at Joint Base Charleston, South Carolina. This project includes the renovation of the Naval Reserve Building 3370 that is used for reserve training 1-2 weekends per month with approximately 250 occupants per weekend. Daily occupancy is about 25 people on a normal usage, and the weekends have high occupancy. The project scope is to replace the HVAC equipment in attempts to eliminate the recent mold growth inside the facility and incidental related work. The humid air has caused the need for temporary de-humidifiers and mold cleanup within the facility. The building currently has numerous HVAC roof top units (RTUs), and the climate control is not working to reduce the high humidity inside the building. A new HVAC system will be designed and any mold or water damaged areas removed, and finishes restored, such as re-painting or replacing ceiling tiles. Cybersecurity is also required for this project Renovation. The renovation shall include providing new HVAC units on the roof and providing any electrical equipment needed to support the new HVAC system, as well as providing duct smoke detectors. A HAZMAT survey was performed to determine the extent of mold that may need to be abated during demolition and refinishing. A plumbing sewer line needs repair at the latrines, to replace it with positive drainage to the existing sewer pump. Dollar magnitude of this requirement is between $1,000,000.00 and $5,000,000.00. The NAICS Code assigned to this acquisition is 2362200 – Commercial and Institutional Building Construction with a Size Standard of $45,000,000.00
Versions on SAM.gov
Source: SAM.gov Contract Opportunities public data file
Posted Mar 18, 2026Sources soughtCurrent version
Respond by Apr 1, 2029, 12:00 PM UTC−4
Changed from the version before: Title, Description
This version on SAM.gov (opens SAM.gov in a new tab)Posted Mar 17, 2026Sources sought
Respond by Apr 1, 2029, 12:00 PM UTC−4
This version on SAM.gov (opens SAM.gov in a new tab)